Bien Airotor - Prestige L

Bien Airotor - Prestige L

bien-air

Availability: In stock

Airotor handpiece
New Rs. 57275

Starting at: Rs.57,275.00

EMI starts from Rs.2,777.07   View Plans >

Bien Air Prestige L Air Rotor

Rs.63,930.00

Rs.57,275.00

Bien Air Prestige L Air Rotor + Unifix 4H L

Rs.75,960.00

Rs.68,000.00


OR
Description

Details

  • Type - Turbine with light, small head
  • Connection - Using 4-way Unifix quick-connect coupling, rotating 360 degree
  • Speed of rotation - 335,000 rpm
  • Recommended air pressure - 3.1 bar
  • Cooling - Diffuser, with 3 separate air and water sprays, water antiretraction valve
  • Chuck locking mechanism - Push-button with anti-heating system
  • Light transmission - Multi-strand optical glass conductor
  • Lighting - Halogen
  • Cleaning/Sterilisation - Thermo washer disinfectable / Steam autoclave up to 135 degree C
  • Weight - 73 g
  • Prestige L ref. - 1600380-001
  • Prestige L + 4-way Unifix set ref. - 1700184-001

 

MAINTENANCE OF TURBINES.

Preparation
A.

REMOVING THE INSTRUMENT

  • Remove the rotary instrument from the chuck mechanism
Tissue_rubbing
B.

PRE-DISINFECTION

  • External disinfection

Do not immerse the instrument in a disinfectant bath.

CLEANING
Cleaning_A
A.

CLEAN UNDER RUNNING WATER AT <38°C

Cleaning_B
B.

REMOVING DIRT/DEPOSITS

  • Carefully remove all traces of dirt or deposits from the spray nozzles using the Bien-Air cleaning wire
  • Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

Do not immerse in an ultrasonic cleaner

Cleaning_CSpraynet-Tissue-spray_CTissue_rubbing_C
C.

INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

  • Shake the Spraynet before use
  • Use the Spraynet attachment 1
    (for 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second
  • Clean the exterior of the turbine with a cloth soaked in Spraynet
FOR 2-/3-WAY AND 4-WAY TURBINES ONLY
Cleaning_C-primeBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways
C'.

CLEANING THE INSIDE WITH SPRAYNET FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the Spraynet attachment 2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second

Spray into the opening as shown in the illustrations for “2-/3-way” and “4-way”

DISINFECTION
Disinfectant-Tissue-spray_ATissue_rubbing_A
A.

DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer's instructions for use)

Do not immerse the instrument in a disinfectant bath

OR
Thermal-disinfector
B.

THERMAL DISINFECTION (follow the manufacturer's instructions for use)

LUBRICATION
Lubrification_A1Lubrification_A2
A.

LUBRICATION WITH LUBRIMED

OR
Lubrification_B1Support_B
B.

LUBRICATION WITH LUBRIFLUID

  • Shake the Lubrifluid before use
  • Use the Lubrifluid attachment 23 ou 4depending on the type of instrument * (For 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second
  • Then, run an operating test for 30 seconds at low speed to remove any surplus lubricant
  • Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out
FOR 2-/3-WAY AND 4-WAY TURBINES ONLY
LubrificationBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways
B'.

INTERNAL LUBRICATION WITH LUBRIFLUID FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the Lubrifluid attachment 2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second

Spray into the opening as shown in the illustrations for “2-/3-way” and “4-way”

STERILISATION
Sterilization
A.

PLACE THE TURBINE IN A STERILISATION BAG

Sterilizer
B.

STERILISE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS

  • Instruments bearing the "135°C" symbol can be sterilised in an autoclave

Only sterilise instruments which have been cleaned and lubricated

 

 
  • Type - Turbine with light, small head
  • Connection - Using 4-way Unifix quick-connect coupling, rotating 360 degree
  • Speed of rotation - 335,000 rpm
  • Recommended air pressure - 3.1 bar
  • Cooling - Diffuser, with 3 separate air and water sprays, water antiretraction valve
  • Chuck locking mechanism - Push-button with anti-heating system
  • Light transmission - Multi-strand optical glass conductor
  • Lighting - Halogen
  • Cleaning/Sterilisation - Thermo washer disinfectable / Steam autoclave up to 135 degree C
  • Weight - 73 g
  • Prestige L ref. - 1600380-001
  • Prestige L + 4-way Unifix set ref. - 1700184-001

 

MAINTENANCE OF TURBINES.

Preparation
A.

REMOVING THE INSTRUMENT

  • Remove the rotary instrument from the chuck mechanism
Tissue_rubbing
B.

PRE-DISINFECTION

  • External disinfection

Do not immerse the instrument in a disinfectant bath.

CLEANING
Cleaning_A
A.

CLEAN UNDER RUNNING WATER AT <38°C

Cleaning_B
B.

REMOVING DIRT/DEPOSITS

  • Carefully remove all traces of dirt or deposits from the spray nozzles using the Bien-Air cleaning wire
  • Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

Do not immerse in an ultrasonic cleaner

Cleaning_CSpraynet-Tissue-spray_CTissue_rubbing_C
C.

INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

  • Shake the Spraynet before use
  • Use the Spraynet attachment 1
    (for 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second
  • Clean the exterior of the turbine with a cloth soaked in Spraynet
FOR 2-/3-WAY AND 4-WAY TURBINES ONLY
Cleaning_C-primeBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways
C'.

CLEANING THE INSIDE WITH SPRAYNET FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the Spraynet attachment 2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second

Spray into the opening as shown in the illustrations for “2-/3-way” and “4-way”

DISINFECTION
Disinfectant-Tissue-spray_ATissue_rubbing_A
A.

DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer's instructions for use)

Do not immerse the instrument in a disinfectant bath

OR
Thermal-disinfector
B.

THERMAL DISINFECTION (follow the manufacturer's instructions for use)

LUBRICATION
Lubrification_A1Lubrification_A2
A.

LUBRICATION WITH LUBRIMED

OR
Lubrification_B1Support_B
B.

LUBRICATION WITH LUBRIFLUID

  • Shake the Lubrifluid before use
  • Use the Lubrifluid attachment 23 ou 4depending on the type of instrument * (For 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second
  • Then, run an operating test for 30 seconds at low speed to remove any surplus lubricant
  • Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out
FOR 2-/3-WAY AND 4-WAY TURBINES ONLY
LubrificationBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways
B'.

INTERNAL LUBRICATION WITH LUBRIFLUID FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the Lubrifluid attachment 2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second

Spray into the opening as shown in the illustrations for “2-/3-way” and “4-way”

STERILISATION
Sterilization
A.

PLACE THE TURBINE IN A STERILISATION BAG

Sterilizer
B.

STERILISE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS

  • Instruments bearing the "135°C" symbol can be sterilised in an autoclave

Only sterilise instruments which have been cleaned and lubricated

 

 
Features
  • QUALITY LED - Adjustable brightness, natural light, no overheating and exceptional resistance to sterilisation
  • DUALOOK - The dual multi-strand optical glass conductor provides the best lighting on the market and is robust enough to withstand all conditions.
  • ACCU-SPRAY - Cooling with 3 sprays with 6 separate air and water nozzles. The ultra-precise nebulisation this offers provides the best possible cooling, and ensures perfect visibility.
  • SEALED HEAD - In combination with the anti-retraction valve, a Tefl on lip prevents any residues or contaminants from entering the instrument.
  • CERAMIC REVOLUTION - Longer service life, greater precision. Less noise, less vibration. Superior quality ceramic ball bearings.
  • ACCU-CHUCK - The most precise bur locking and rotation drive technology in the world. Discover instruments with no imbalance or vibration.
  • COOL TOUCH - Push-button with an anti-heating safety system. This reduces the risk of burning your patients with the head of your instrument. For your comfort and your patients safety.
  • SOFT PUSH Bien- Air's unique push-button insert and clamp locking mechanism. Light pressure is all that's required. Bur changing is quick, comfortable, safe and accurate.
  • FREE MOVE - The Bien-Air turbine-hose combination offers a freedom of movement conducive to working comfort, thanks to the light and flexible rotating coupling.
Key Specifications
  • Authentic
  • Reliable
  • Guarantee impeccable hygiene
  • Simple and Unique
Warranty
Manufacturer/Importer warranty of 12 Months applicable for this product. Service and Warranty are handled by the manufacturer/importer directly for this product
packaging
  • 1 unit
Additional Information

Additional Information

Dispatch Date Next Day
COD Yes
FAQs N/A
Reviews

Related Products

There are no products matching the selection.

You may also be interested in

D-Tech Bracket Tweezer
d-tech bracket tweezer
Bracket Tweezer
  • Rs.500.00

    Rs.332.00

    33.6% off

Sold out

Gdc Elastic Ligature Applicator #1 (674)
gdc elastic ligature applicator #1 (674)
OrthodonticInstrument
  • Rs.308.00

    Rs.238.00

    22.7% off
D-Tech Iono Prep
d-tech iono prep
Dentin Conditioner
  • Rs.237.00

    Rs.213.00

    10.1% off

Sold out

J Morita Tri Auto ZX 2 Endo Motor ( With Apex Locator)
j morita tri auto zx 2 endo motor ( with apex loca...
(ENDOMOTOR WITH BUILT-IN APEX LOCATOR)
  • Rs.175,000.00

    Rs.157,311.00

    10.1% off
Gdc Cassette For 4 Instruments (Imsca4)
gdc cassette for 4 instruments (imsca4)
InstrumentAccessories
  • Rs.2,541.00

    Rs.2,020.00

    20.5% off
Gdc Dentulous Perforated Impression Trays Upper # 3 (Itrldpu3)
gdc dentulous perforated impression trays upper # ...
ImpressionTrays
  • Rs.352.00

    Rs.297.00

    15.6% off
Samit Fox Plane Plastic
samit fox plane plastic
Fox Plane Plastic
  • Rs.100.00

    Rs.70.00

    bulk price: Rs.60.00
    30% off
Waldent Protaper Hand files
waldent protaper hand files
Ni-Ti protaper hand files (Pack of 6 fil...
  • Starting at: Rs.1,050.00

    55.8% off

Recently Viewed Products