Vita VMK Master Dentine Classical shades:

For Simple minimal powder buildups to the more complex cases with individual characteristics vita vmk master's optimum firing temperature and chemical and physical properties make it suitable for veneering nearly all types of dental alloys including non-precious working with the new vita vmk master offers some important advantages including.

  • Excellent working properties including improved modeling characteristics easy and fast handling and minimal shrinkage
  • Accurate and outstanding esthetic results with traditional layering technique
  • Wide selection of additional porcelains including luminaries to enhance fluorescence translucent porcelains to reproduce the translucency of natural tooth enamel, neck modifiers to simulate the cervical third gingival porcelains to simulate tissue color and opal and pearl modifiers to achieve true youthful and bleached teeth

 

Vita VMK Master Dentine Classical shades:

For Simple minimal powder buildups to the more complex cases with individual characteristics vita vmk master's optimum firing temperature and chemical and physical properties make it suitable for veneering nearly all types of dental alloys including non-precious working with the new vita vmk master offers some important advantages including.

  • Excellent working properties including improved modeling characteristics easy and fast handling and minimal shrinkage
  • Accurate and outstanding esthetic results with traditional layering technique
  • Wide selection of additional porcelains including luminaries to enhance fluorescence translucent porcelains to reproduce the translucency of natural tooth enamel, neck modifiers to simulate the cervical third gingival porcelains to simulate tissue color and opal and pearl modifiers to achieve true youthful and bleached teeth

 

Features
  • A material that makes no compromises when it comes to reliability and esthetics
  • Precise and reliable processing, allowing it to be learned quickly
  • Excellent processing characteristics, such as improved modeling properties, simple handling and minimum shrinkage behavior
  • Conventional, established dentin-incisal layering system
  • Comprehensive range of additional materials for individualization
  • Highly esthetic restorations thanks to brilliant colors
packaging
  • 1 x 50g Bottle
Additional Information

Additional Information

Dispatch Date Next Day
Expiry Date Dentalkart believes in providing the Longest Expiry available for the demanded product. Please Note: Minimum 1 year Or Maximum 2-3 years long expiry will certainly be provided.
COD Yes
FAQs
Tearing

Please check the following which could have caused
the problem:

  • Model in reduced tooth size particularly in the case of molars and bridges in order to achieve a homogeneous layer thickness of the ceramic. Ensure cuspal support in the posterior area, and U-shaped modellation of the interdental spaces.
  • Casting: ensure correct flame adjustment and temperature of induction or electronic casting equipment. Use the casting crucible and temperature recommended for the alloy.
  • Never mix alloys. Do not use more than one third of old metal.
  • Make sure to use clean sandblasting material and observe the manufacturer's instructions. Do not use any circuit blasting units.
  • Finish the entire surface of the crown or bridge in order to remove any reaction products of the alloy surface and the investment material or impurities in the surface. Finish the interdental spaces.
  • Various manufacturers no longer recommend oxidation firing. However, when changing alloys, oxidation firing should be carried out. It serves to check the oxide color, which must be homogeneous with the shade. There must be no stains or discolorations on the surface to be veneered. The oxide layer can be subsequently removed by sandblasting or etching.
  • When mixing all ceramic materials, ensure that no bubbles are formed. Ensure that the liquid is added to the powder from the side and the material is mixed thoroughly using a glass or agate spatula. The use of metal spatulas can lead to metal abrasion and discoloration of the ceramic.
  • Keep workplace clean: metal dust and dirty brush water can lead to problems.
  • Application of insulating liquid should not be too thick.
  • When firing bridges, always separate down to the opaque at the first firing. Shrinkage of the ceramic always occurs only in the thickest area. Therefore a uniform layer thickness is recommended. Do not use any dry or saw-toothed instruments. The use of these instruments can cause the ceramic to become detached and separated from the surface.
  • Ensure correct firing parameters and firing temperature. Carry out muffle test by using a mirror to see if the muffle is properly heated from all sides in the firing chamber.
  • If a rubber polisher is used before the final finishing, the surface must not be wetted with liquid again. It must first be cleaned. It is not sufficient to clean it using a steam cleaner or with water. Silicone residue at the surface must be removed mechanically.
  • Insulating material residue must not be on the ceramic surface. Contact with the freshly insulated antagonist teeth may also lead to problems.
  • When filling the interdental spaces during bridge correction, do not vibrate the material until dry; otherwise the material will not bond. Interdental spaces should be wetted with an oily liquid (e.g. VITA INTERNO) before filling.
Discolorations

Please check the following which could have caused
the problem:

  • Observe information on storage, expiration dates and processing of the investment material.
  • Casting: ensure correct flame adjustment and temperature of induction or electronic casting equipment. Use the crucibles and temperature recommended for the alloy.
  • Use the crucibles recommended for the alloy.
  • Ensure homogeneous metal structure; if possible avoid soldering or lasering.
  • Use recommended ceramic mixing liquid and observe the firing temperature.
 
Marginal recessions

Please check the following which could have caused
the problem:

  • Model in reduced tooth size particularly in the case of molars and bridges in order to achieve a homogeneous layer thickness of the ceramic. Ensure cuspal support in the posterior area, and U-shaped modellation of the interdental spaces.
  • The opaque must be applied in accordance with the working instructions. To ensure proper melting of the opaque, the correct temperature must be adhered to.
  • Avoid bubbles or discolorations at the surface of the opaque.
  • Ensure good marginal adaptation of the ceramics; if necessary brush the ceramic in these areas before firing (use a dry brush).
  • When firing bridges, always separate down to the opaque for the first firing. Shrinkage of the ceramic always occurs only in the thickest area. Therefore a uniform layer thick ness is recommended. Do not use any dry or saw-toothed instruments. The use of these instruments can cause the ceramic to become detached and separated from the surface.
  • Should a rubber polisher be used before the final finishing, the surface must not be wetted with liquid again. It must first be cleaned. It is not sufficient to clean it using a steam cleaner or with water. Silicone residue at the surface must be removed mechanically.
  • Insulation material residue must not be on the ceramic surface. Contact with the freshly-insulated antagonist teeth (opposing jaw) can lead to problems.
Clouding in the ceramic

Please check the following which could have caused
the problem:

  • Ensure correct firing parameters and firing temperature. Carry out muffle test with mirror to see if muffle is properly heated from all sides.
  • Insulation material residue must not be on the ceramic surface. Contact with the freshly insulated antagonist teeth (opposing jaw) can lead to problems.
  • The correction porcelain should not be applied in very small portions. Make sure it does not dry out too much; if necessary use a liquid which keeps it moist longer.
  • Firing temperature is too low.
  • Avoid constant suction and rewetting of the mixture; ensure homogeneous moisture level.
 
Deformation of substructures

Please check the following which could have caused
the problem:

  • General preparation guidelines must be observed.
  • When modelling in wax, the minimum layer thicknesses should be adhered to right from the beginning to ensure that sufficient material remains also after finishing.
  • Observe manufacturers' instructions regarding alloys.
  • Non precious metal alloys and high gold content alloys require different wall thicknesses.
  • Sprueing of the modellation according to the manufacturer's instructions.
  • Observe information on storage, expiration dates and processing of the investment material.
  • Observe the manufacturer's instructions on processing of the respective metal (alloy).
  • Ensure correct firing parameters and firing temperature. Carry out muffle test with mirror to see if muffle is properly heated from all sides.
  • Ensure correct flame adjustment and temperature of induction or electronic casting equipment.
  • Use the casting crucible recommended for the alloy. Do not cast different alloys in a single crucible.
  • Never mix alloys. Do not use more than one third of old metal.
Reviews

Related Products

There are no products matching the selection.

You may also be interested in

Vita Akzent Plus Glaze LT
vita akzent plus glaze lt
Akzent Plus Glaze LT
  • Rs.1,501.00
Vita Easyshade Advance 5
vita easyshade advance 5
Easyshade : The 4th Generation Electroni...
  • Rs.1,560,000.00

    Rs.105,000.00

    93.3% off
Vita VMK Master Opaque Classical Shades
vita vmk master opaque classical shades
VMK Master Opaque Classical Shades
  • Rs.2,240.00

    Rs.2,000.00

    10.7% off
Vita VMK Master Dentine Classical shades
vita vmk master dentine classical shades
VMK Master Dentine Classical shades
  • Rs.2,240.00

    Rs.2,000.00

    10.7% off
Vita Toothguide 3d-Master With Bleached Shades
vita toothguide 3d-master with bleached shades
TOOTH GUIDE (EFFICIENT SHADE DETERMI.TIO...
  • Rs.5,500.00

    Rs.4,675.00

    15% off
Vita Opaque Fluid
vita opaque fluid
Opaque Fluid
  • Rs.3,500.00
Vita Linearguide 3d-Master Shade Guide
vita linearguide 3d-master shade guide
Linear, Bleached &Tooth guide. Efficient...
  • Rs.16,200.00

    Rs.13,608.00

    16% off
Vita Classical Shade Guide
vita classical shade guide
Shade Guide (accurate tooth colour deter...
  • Rs.5,500.00

    Rs.4,565.00

    17% off
Vita VMK Master Paste Opaque
vita vmk master paste opaque
VMK Master Paste Opaque
  • Rs.2,240.00

    Rs.1,800.00

    19.6% off
Vita Vionic Denture Base Disc
vita vionic denture base disc
Denture Base Disc for efficient CAD/CAM ...
  • Starting at: Rs.8,625.00

Recently Viewed Products